Customer Code | Loads your customer image (logo, colors etc.); by default it is ARVIKON. If left blank, ARVIKON is loaded. |
Automatic functions | When enabled this feature allows the system to act automatically on certain risks, for example: - Turn off water pump when it marks level 0%
- Turn off power consumption when battery voltage is low
- Activate the System Frost Protect when the temperature is low
- Etc..
|
Instantaneous currents | This function, when active, makes possible to see in real time the current of each output in the fuse window itself. Each fuse will indicate, below the fuse symbol, the instantaneous current. It is deactivated automatically in the first RESET or after a certain time. |
Changing fuse values | This function makes possible to change the cut-off values of digital fuses. The limits are assigned by ARVIKON but you can change them to your wish within the limits. |
Internal load management (max 30A booster) | By activating this function, the current of the booster can circulate through the CORE plate between terminals B1 and B2. If ARVISHUNT is being used, this feature must be disabled. If 30A of current through the ARVICORE is exceeded, it can cause a breakdown. |
Activate refrigerator temperature reading | If the refrigerator temperature probe is being used, this reading must be enabled. If it is not used and disabled, no refrigerator temperature will be displayed. |
100% clean water setting (SET) | This function is used to make an adjustment of water probes of the type 0-180ohm and CBE. With the tank full of water you must press this button that will flash confirming the SET. |
100% sewage adjustment (SET) | This function is used to make an adjustment of water probes of the type 0-180ohm and CBE. With the tank full of water you must press this button that will flash confirming the SET. |
ARVICORE hardware vision | This function is used to adjust some parameters to the appropriate hardware: you can see the hardware version you have installed on the board itself, located in the center of it. |
Base value of consumption in AMP | This field allows you to set a base value of the consumption in amperes that has been installed in the vehicle. If we know the value in amps that the battery gives us because there are things installed outside the ARVIKON system, we can indicate it here. By default, the default value that will be indicated is 0.4 A, which corresponds to the ARVIKON system’s own consumption. |
Sensitivity of screw probes | With this function it is possible to adjust the sensitivity with which the system makes the readings of the screws. This value should be adjusted depending on how close the screws are to each other or the type of water it will contain. |