Description
Mark: Webasto
Model: AIR ADAPTATIVE
CONNECTION: ANALOGUE
EXPLANATION:
When a fan system is used to extract heat from a heat exchanger which in turn is heated by a thermo top.
In this way, when the heating is activated and a temperature is selected, the system will activate the output of pin 5 and 6 of block 28 with a PWM regulation to modulate the fan speed.
The temperature reading will be taken by the probe inside the vehicle, the closer to the target the slower the air will move.
The system will automatically start the boiler if the user turns on the heat, as well as, it will warn the user when he/she tries to turn off the boiler with the heat on.
CONNECTION:
BLOCK 28 |
1 | NO USE | ||
2 | NO USE | |||
3 | NO USE | |||
4 | NO USE | |||
5 | – | GND FAN | BLACK | |
6 | + | +12VDC FAN | YELLOW (LOW POWER) |
CONNECTION DIAGRAM:
![]() |
ATTENTION: A 10A 50V DIODE NOT INCLUDED MUST BE MOUNTED. FAILURE TO MOUNT THE PROPER DIODE OR USE THE MEDIUM AND HIGH FAN POWERS WILL DAMAGE THE ARVICORE BOARD AND VOID THE WARRANTY. |
CONFIGURATION:
Go to “Professional Settings” and select:
Boiler model: WEBASTO THERMO TOP
Heating model: WEBASTO THERMO TOP AIR ADAPTATIVE