Description
Mark: Webasto
Model: THERMOTOP EVO 4GEN
CONNECTION: ANALOGUE
CONNECTION:
The power cables and the analog signal cable of the thermotropic will be used.
BLOCK 27 |
1 | + | 12VDC | RED |
2 | – | GND | BLACK | |
3 | SIGN | UNUSED | — | |
4 | SIGN | RUN SIGNAL (PIN3 BLOCK X1) | GRAY | |
5 | SIGN | UNUSED | — | |
6 | SIGN | UNUSED | — | |
7 | SIGN | UNUSED | — | |
8 | SIGN | UNUSED | — |
In case of increasing the cable distance, the cross-section must be properly calculated.
CONNECTION DIAGRAM:
CONFIGURATION:
Go to “Professional Settings” and under BOILER, select WEBASTO THERMO TOP.
This type of connection does not allow error reading or diagnostics.